Summary: In an electrical arc flash, the head, face, eyes and neck are exposed to extreme heat and radiant energy. Arc-rated jackets and trousers protect the torso and limbs, but a worker whose head and neck are unprotected can still suffer severe burns.
Standard safety glasses and everyday hard hats do not protect against the heat of an arc flash.
Workers are only fully protected when they are covered from head-to-foot®. A complete arc flash safety plan pairs arc-rated body garments with certified headwear, such as balaclavas, arc-rated face shields and switching hoods, matched to the site’s calculated incident energy.
Why Is Head and Neck Protection Important in Arc Flash Environments?
When an electrical fault causes an arc flash, the surrounding air heats up almost instantly, producing intense thermal energy and blast pressure. Because electrical workers must stand close to panels, switchgear or open conductors to perform maintenance, the head, face and hands are closest to the hazard.
Even when workers wear arc-rated clothing on their body, an exposed throat, chin or ear can result in serious burns.
In short: Arc flash head protection shields the face, eyes, head and neck from the intense heat of an arc flash, and is a key part of a complete, head-to-foot® protective system.
CHARNAUD®’s SURVIVE-ARC® range includes balaclavas, arc-rated goggles, face shields and full switching hoods made in several protection levels to suit different risks.
Core Criteria for Choosing Arc Flash Head Protection
Selecting the right head and neck protection comes down to three main points: covering all vulnerable areas, matching the gear to your assessed incident energy, and making sure it integrates smoothly with the rest of your PPE.
1.Covering Vulnerable Areas Without Gaps
An arc flash radiates heat in all directions, so any opening around the neckline or face is an easy route for thermal injury. A standard hard hat protects against falling tools, but leaves the sides of the face, the neck and the ears completely open.
Effective head protection closes these gaps. For lower-to-medium risk work, an arc-rated balaclava should extend well past the neck to tuck securely beneath the jacket collar.
CHARNAUD®’s SURVIVE-ARC® single-layer balaclava has an ATPV of 12.1 cal/cm² and covers the face and neck down to the shoulders, leaving openings for the eyes to pair with arc-rated goggles. For higher exposures, our double-layer 28.2 cal/cm² balaclavas give more thermal protection..
2. Matching the Head Gear Rating to Your Arc Flash Study
Head protection must be selected to match or exceed the incident energy calculated in your facility’s arc flash risk assessment:
- Low-to-Medium Energy Work: Routine tasks often require an arc-rated balaclava combined with an arc-rated face shield or arc goggles and an electrical-rated hard hat.
- High-Energy Switching Tasks: Working on heavy switchgear or high-voltage breakers requires a complete CAT 4 switching hood. These hoods use multi-layer thermal fabric, an integrated arc-rated visor and an internal dielectric hard hat to give 360-degree coverage.
CHARNAUD® SURVIVE-ARC® headgear is tested to recognised standards, such as, EN 61482-2 for garments and ASTM F2178, for arc- rated eye and face products.
3. Fitting into a Coordinated Head-to-Foot® System
Head PPE should never be viewed on its own. A common issue on site is choosing a hood or balaclava that does not fit neatly with the jacket collar, leaving the throat exposed when a technician looks up or turns their head.
Under CHARNAUD®’s head-to-foot® approach, SURVIVE-ARC® balaclavas, hoods, jackets and trousers are shaped to overlap cleanly. This keeps coverage continuous as the worker moves and still leaves room for hearing protection and safety footwear.
Key Arc Flash Head Protection Considerations for Electrical Workers
Safety officers and procurement teams should check the following when selecting PPE for the head and face:
| What to check | What it means in practice | Why it matters |
|---|---|---|
| Risk assessment match | Choose balaclavas or hoods with an ATPV rated at or above your site’s calculated energy. | Prevents under-protecting workers during higher-energy switching tasks. |
| Full neck and bib coverage | Make sure balaclavas tucked deep inside the garment collar. | Stops radiant heat from reaching bare skin when bending or turning. |
| Visor clarity and tint | Use arc-rated visors that offer good light transmission and clear colour balance. | Helps electricians identify wiring colours correctly and work safely in dim areas. |
| Dielectric safety | Check that all headgear, hard hats and fasteners contain no conductive metal parts. | Reduces the risk of electricity conducting through your PPE. |
| Comfort and ventilation | Select breathable balaclavas and hoods with good ventilation. | Helps reduce visor fogging and workers who are comfortable keep their gear on. |
| Care and inspection | Follow manufacturer wash instructions and inspect visors and fabric for cracks or damage. | Scratched visors or degraded fabrics may not protect as rated. |
Frequently Asked Questions
Can normal safety glasses and a standard hard hat protect against an arc flash?
No. Standard safety glasses and site hard hats are made for mechanical impacts from flying chips or falling tools. They have no dielectric properties , and ordinary plastics can melt or catch fire in extreme heat.
What is the difference between an arc flash balaclava and a switching hood?
An arc-rated balaclava is a flexible, flame-resistant knit worn under a hard hat in combination with arc goggles or a face shield for low-to-medium hazard tasks. A switching hood is a complete, bee-hive type enclosure that covers the head, neck and shoulders, featuring a visor and dielectric hard hat for high-energy work.
Can arc flash head protection be worn on its own?
No. CHARNAUD® states that its head protection must form part of an appropriate set of protective clothing and PPE to provide adequate protection from the thermal effects of an arc flash. A hood or balaclava protects the face and neck, but must be paired with arc-rated jackets, trousers, switching gloves and electrical safety boots to ensure head-to-foot coverage.
How do I know which cal rating to choose for head protection?
Your required rating depends on the calculated incident energy from your workplace arc flash assessment. Your head and face protection must meet or exceed that number. For example, if your task is assessed at 10 cal/cm², you need head and face protection rated at 10 cal/cm² or more such as a 12.1 cal/cm² balaclava with 12.1 cal/cm² goggles. The lowest-rated item sets the rating of the whole ensemble provides the required margin of safety.
Partner with CHARNAUD® for Arc Flash Head Protection Solutions
CHARNAUD® manufactures certified SURVIVE-ARC® protective wear for electrical workers facing arc flash hazards. Our range of balaclavas, visors, switching hoods and full suits, gives certified head-to-foot protection for industrial and mining work.
Equip your team with tested head and face protection suited to the real hazards at your site.